Advanced Search
Volume 39 Issue 1
Jan.  2017
Turn off MathJax
Article Contents
CAO Lin, CHEN Houjin, LI Jupeng, CHENG Lin. Physiological Features Based Coordinate System for Multi-view Analysis in Mammograms[J]. Journal of Electronics & Information Technology, 2017, 39(1): 176-182. doi: 10.11999/JEIT160193
Citation: CAO Lin, CHEN Houjin, LI Jupeng, CHENG Lin. Physiological Features Based Coordinate System for Multi-view Analysis in Mammograms[J]. Journal of Electronics & Information Technology, 2017, 39(1): 176-182. doi: 10.11999/JEIT160193

Physiological Features Based Coordinate System for Multi-view Analysis in Mammograms

doi: 10.11999/JEIT160193
Funds:

The National Natural Science Foundation of China (61271305), Beijing Municipal Science and Technology Project (D151100000415002), The Fundamental Research Funds for the Central Universities (2015JBM015)

  • Received Date: 2016-03-01
  • Rev Recd Date: 2016-07-08
  • Publish Date: 2017-01-19
  • A breast coordinate system based on physiological features is developed for multi-view analysis in mammograms. It is constructed according to the locations of nipple, pectoral muscle and the fitted breast boundary. The breast regions in mammograms are mapped into a parameter frame because of the coordinate system. Experiments are implemented on data set of Breast Cancer of Peking University Peoples Hospital. The performance of locating the physiological features and matching the regions of interest is evaluated. Results show that the proposed coordinate system could achieve favorable performance and facilitate the multi-view analysis in mammograms.
  • loading
  • ANDERSON B O, YIP C H, SMITH R A, et al. Guideline implementation for breast healthcare in low-income and middle-income countries[J]. Cancer, 2008, 113(S8): 2221-2243. doi: 10.1002/cncr.23844.
    MASKARINEC G, MENG L, and URSIN G. Ethnic differences in mammographic densities[J]. International Journal of Epidemiology, 2001, 30(5): 959-965. doi: 10.1093 /ije/30.5.959.
    MENCATTINI A, SALMERI M, and CASTI P. Bilateral asymmetry identification for the early detection of breast cancer[C]. 2011 IEEE International Workshop on Medical Measurements and Applications Proceedings (MeMeA), Bari, Italy, 2011: 613-618. doi: 10.1109/MeMeA.2011.5966746.
    CASTI P, MENCATTINI A, SALMERI M, et al. Masking procedures and measures of angular similarity for detection of bilateral asymmetry in mammograms[C]. The 4th IEEE International Conference on E-Health and Bioengineering, Iasi, Romania, 2013: 1-4. doi: 10.1109/EHB.2013.6707258.
    CASTI P, MENCATTINI A, SALMERI M, et al. Analysis of structural similarity in mammograms for detection of bilateral asymmetry[J]. IEEE Transactions on Medical Imaging, 2015, 24(2): 662-671. doi: 10.1109/TMI.2014. 2365436.
    MAGNA G, JAYARAMAN S V, CASTI P, et al. Adaptive classification model based on artificial immune system for breast cancer detection[C]. 2015 XVIII AISEM Annual Conference, Trento, Italy, 2015: 1-4. doi: 10.1109/AISEM. 2015.7066842.
    LI Yanfeng, CHEN Houjin, YANG Yongyi, et al. A bilateral analysis scheme for false positive reduction in mammogram mass detection[J]. Computers in Biology and Medicine, 2015, (57): 84-95. doi: 10.1016/j.compbiomed.2014.12.007.
    KELDER A, ZIGEL Y, LEDERMAN D, et al. A new computer-aided detection scheme based on assessment of local bilateral mammographic feature asymmetry-a preliminary evaluation[C]. 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Milan, Italy, 2015: 6394-6397. doi: 10.1109/EMBC. 2015.7319856.
    王之琼, 王培, 于戈, 等. 双侧特征融合的乳腺肿块检测[J]. 计算机辅助设计与图形学学报, 2015, 27(6): 1024-1031.
    WANG Zhiqiong, WANG Pei, YU Ge, et al. Breast tumor detection on fusion of bilateral feature[J]. Journal of Computer-Aided Design Computer Graphics, 2015, 27(6): 1024-1031.
    CAO Lin, CHEN Houjin, LI Jupeng, et al. A coordinate system for multi-view analysis of mammograms[C]. The 6th International Conference on Mechanical and Electronics Engineering, Beijing, China, 2014: 481-487. doi: 10.2495/ ICMIIE140701.
    BRANDT S S, KAREMORE G, and KARSSEMEIJER N. An anatomically oriented breast coordinate system for mammogram analysis[J]. IEEE Transactions on Medical Imaging, 2011, 30(10): 1841-1851. doi: 10.1109/TMI.2011. 2155082.
    GEORGSSON F. Anatomical coordinate system for bilateral registration of mammograms[C]. 13th Scandinavian Conference on Image Analysis, Halmstad, Sweden, 2003: 335-342. doi: 10.1007/3-540-45103-X_46.
    KITA Y, HIGHNAM R, and BRADY M. Correspondence between different view breast X rays using curved epipolar lines[J]. Computer Vision and Image Understanding, 2001, 83(1): 38-56. doi: 10.1006/cviu.2001.0908.
    PU Jiantao, ZHENG Bin, LEADER J K, et al. An ellipse- fitting based method for efficient registration of breast masses on two mammographic views[J]. Medical Physics, 2008, 35(2): 487-494. doi: 10.1118/1.2828188.
    MARTIN K E, HELVIE M A, ZHOU C, et al. Mammographic density measured with quantitative computer-aided method comparison with radiologists estimates and BI-RADS categories[J]. Radiology, 2006, 240(3): 656-665. doi: 10.1148/radiol.2402041947.
    WIRTH M A, CHOI C, and JENNINGS A. A nonrigid-body approach to matching mammograms[C]. Seventh International Conference on Image Processing and Its Applications, Manchester, UK, 1999: 484-488. doi: 10.1049/ cp:19990369.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1448) PDF downloads(521) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return