微波前列腺治疗仪的研制
DEVELOPMENT OF MICROWAVE PROSTATE THERAPY
-
摘要: 本文阐述了微波前列腺治疗仪的原理和设计,采用频率为915MHz的微波对前列腺进行热疗。特殊设计的固态微波源和表面冷却技术,使加热区仅局限在前列腺上。特制的治疗导管和辐射器,可以实现经尿道或经直肠进行治疗。所用的热敏传感器的测温精度可达0.1℃,运用微型计算机对治疗的全过程进行自动测温、控温,并实时记录、显示、打印治疗参数和病例资料管理。
-
关键词:
- 微波热疗; 前列腺治疗; 导管; 测温
Abstract: The therapy principle and design of microwave prostate hyperthermia are described. This apparatus uses 915MHz microwave treatment for the prostate. The solid state microwave source and surface cooling system of special design only heats the prostate. The specially designed Foley duct and microwave radiator can be used for treatment by transurethral or transrectal. The temperature is measured and monitered automatically, and the measured data are recorded, displayed and printed in real-time by a microcomputer. The accuracy of thermosensor measurements is 0.1℃. -
郭应禄.腔内泌尿外科学.北京:人民军医出版社,1992, 90-98.[2]郭应禄,葛霁.前列线热疗及其相关疗法.北京:学苑出版社,1993,第三篇,第一章.[3]陈代珠.医用微波技术.北京:国防工业出版社,1987,第四章.[4]刘普和,等.医学物理学.北京:人民卫生出版社,1980,504.